4 years ago Water Meter Itron Water Meter Itron Nominal Diameter : 1/ 2 ” – 3/ 4 ” ( 15 – 20 mm ) Starting Flow Rate : 10 – 12 l/ h Max. Pressure : 16 bar Max. Flow Rate : 3 – 5 m3/ h Max. Temperature : 40 degree C Nominal Diameter (DN) mm pol 15 1/2″ 20 3/4″ Length mm 165/170/190 190 Metrology Class B C B C Typical Start Up L/H 10 7 18 12 Minimum Flow Rate – Qmin L/H 30 15 50 25 Transitional Flow Rate – Qt L/H 120 22,5 200 37,5 Nominal Flow Rate – Qn m3/h 1,5 1,5 2,5 2,5 Maxiumum Flow Rate – Qmax m3/h 3 3 5 5 Maximum Temperature °C 40 Maximum Temperature (<1h) °C 50 Maximum Operating Pressure bar 16 Head Loss at Qmax bar <1 Maximum Reading m3 9,999 or 99,999 Minimum Reading L 0,02